Estudio de la densidad, porcentaje de absorción, y vacíos del concreto cemento – arena empleando la norma ASTM C 642, Iquitos - 2021

Mostrar el registro sencillo del ítem

dc.contributor.advisor Irigoin Cabrera, Ulises Octavio
dc.contributor.author Álvarez Hilorio, Stefany Smith
dc.contributor.author Coriat Zavaleta, Christian Gerard
dc.date.accessioned 2021-09-27T14:52:36Z
dc.date.available 2021-09-27T14:52:36Z
dc.date.issued 2021-07-24
dc.identifier.uri http://hdl.handle.net/20.500.14503/1428
dc.description.abstract Estudio de la densidad, porcentaje de absorción, y vacíos del concreto cemento – arena empleando la norma ASTM C 642, Iquitos - 2021 Para el concreto cemento – arena cuyo uso predomina en la Selva Baja peruana, no existían estudios que evalúen las propiedades en estado endurecido de densidad, porcentaje de absorción y porosidad (porcentaje de vacíos), razón que justificó la realización de la presente investigación. Como materiales se utilizó arena fina de 1.27 de módulo de finura, cemento portland tipo GU (APU). Se elaboró 36 especímenes de concreto cemento – arena, de 4”x8”, preparados para 0.60, 0.65 y 0.70 de relaciones agua/cemento. Para determinar la resistencia a la compresión se utilizó la norma ASTM C 39, efectuándose la rotura de 5 especímenes por cada relación agua/cemento, a los 7 y 28 días. Para la determinación de la densidad, porcentaje de absorción y porosidad se empleó la norma ASTM C 642, efectuándose cada uno de estos ensayos en un solo espécimen a los 7 y 28 días. Y la realización de los ensayos complementarios para determinar el contenido de aire del concreto y la temperatura del concreto en estado recién mezclado mediante las normas ASTM C 138 y ASTM C 1064 respectivamente. De los resultados obtenidos, se puede concluir que, a mayor relación a/c, el concreto cemento – arena adquiere semejante densidad que el concreto normalizado, pero mayor absorción y porosidad, asimismo, menor resistencia a la compresión. Del análisis de los fragmentos resultantes de la rotura de cada probeta, la parte superior presentó baja densidad, alta absorción y alta porosidad, y, el fragmento inferior resultó poseer una mayor densidad, pero baja absorción y baja porosidad. es_ES
dc.description.abstract Study of the density, absorption percentage, and voids of cement-sand concrete using the ASTM C 642 standard, Iquitos - 2021 For cement-sand concrete, the use of which predominates in the Peruvian Low Forest, there were no studies evaluating the properties in the hardened state of density, percentage of absorption and porosity (percentage of voids), a reason that justified the conduct of the present investigation. The materials used were fine sand with a modulus of fineness of 1.27, portland cement type GU (APU). 36 4 "x8" cement-sand concrete specimens were made, prepared for 0.60, 0.65 and 0.70 water / cement ratios. To determine the compressive strength, the ASTM C 39 standard was used, breaking 5 specimens for each water / cement ratio, at 7 and 28 days. For the determination of density, absorption percentage and porosity, the ASTM C 642 standard was used, each of these tests being carried out on a single specimen at 7 and 28 days. And the performance of complementary tests to determine the air content of the concrete and the temperature of the concrete in the freshly mixed state by means of the ASTM C 138 and ASTM C 1064 standards respectively. From the results obtained, it can be concluded that, with a higher w / c ratio, cement-sand concrete acquires a similar density than normalized concrete, but greater absorption and porosity, as well as lower resistance to compression. From the analysis of the fragments resulting from the breakage of each specimen, the upper part presented low density, high absorption and high porosity, and the lower fragment turned out to have a higher density, but low absorption and low porosity. En_us
dc.description.uri Trabajo de suficiencia profesional es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Científica del Perú es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Densidad es_ES
dc.subject Absorción es_ES
dc.subject Vacíos (porosidad) es_ES
dc.subject Density En_us
dc.subject Absorption En_us
dc.subject Voids (porosity) En_us
dc.title Estudio de la densidad, porcentaje de absorción, y vacíos del concreto cemento – arena empleando la norma ASTM C 642, Iquitos - 2021 es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Ingeniero Civil es_ES
thesis.degree.grantor Universidad Científica del Perú. Facultad de Ciencias e Ingeniería es_ES
thesis.degree.level Titulo Profesional es_ES
thesis.degree.discipline Ingeniería Civil es_ES
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#2.01.00 es_ES
dc.publisher.country PE es_ES
renati.advisor.orcid https://orcid.org/0009-0007-6168-7415 es_ES
renati.advisor.dni 10190397 es_ES
renati.author.dni 72268974 es_ES
renati.author.dni 71002782 es_ES
renati.type https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional es_ES
renati.level http://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 732267 es_ES
renati.juror Ocaña Aponte, Juan Jesús es_ES
renati.juror Arévalo Flores, Jefree Stefano es_ES
renati.juror Gallardo Sánchez, Nerea es_ES


Ficheros en el ítem

El ítem tiene asociados los siguientes ficheros de licencia:

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess

Buscar en DSpace


Listar

Mi cuenta

Estadísticas