Modelo de aplicación tecnológica para la estabilización de taludes en la cámara de bombeo pluvial Nº01 del hospital II-2 Cesar Garayar García, Iquitos 2021

Mostrar el registro sencillo del ítem

dc.contributor.advisor Robalino Osorio, Miguel Angel
dc.contributor.author Sernaqué Vargas, Hugo Jeffer
dc.contributor.author Nuñez Vargas, Joyce Llolaos
dc.date.accessioned 2022-06-14T14:06:10Z
dc.date.available 2022-06-14T14:06:10Z
dc.date.issued 2022-03-02
dc.identifier.uri http://hdl.handle.net/20.500.14503/1850
dc.description.abstract El siguiente estudio permitió elaborar un modelo de aplicación tecnológica para estabilizar los taludes generados al momento de iniciar la construcción de la cámara de bombeo pluvial Nº01 del Hospital II-2 Cesar Garayar García-Iquitos, la existencia de una potencial falla hizo de que los trabajos que se venían ejecutando sean suspendidos hasta garantizar la estabilidad de los taludes, para conseguir este objetivo inicialmente se realizó una inspección visual, posteriormente se calculó el factor de seguridad de los taludes en estado natural, utilizando como datos geotécnicos las propiedades del suelo de fundación obtenidos mediante los ensayos de SPT. El cálculo del factor de seguridad se obtuvo utilizando el método de las dovelas con infiltración establecida, esto debido a que en la zona de estudio se cuentan con suelos tropicales, se analizaron tres posibles planos de fallas dando como resultados factores de seguridad menores a 1.00 lo que según el Reglamento Nacional de Edificaciones (E050-art. 30) nos indica un factor de seguridad inferior al mínimo recomendado en condiciones estáticas, posteriormente se evaluaron las muestras en estudio pero esta vez considerando el modelo propuesto que consiste en estabilizar los taludes utilizando pilotes de acero estructural y malla metálicas, obteniendo como resultados factores de seguridad mayores a 4.00 que indican estabilidad en los taludes, siendo valores aceptados según norma. Además de acuerdo al estudio de factibilidad elaborado en el presente trabajo, tenemos una factibilidad económica de 36.02% utilizando el modelo propuesto en el proyecto. Este porcentaje de rentabilidad supera las otras alternativas convencionales por lo que desde esta perspectiva el modelo es factible. es_ES
dc.description.abstract The following study made it possible to develop a model of technological application to stabilize the slopes generated at starting time the construction of the rain pumping chamber N° 01 of Hospital II-2 Cesar Garayar García-Iquitos, the existence of a potential failure caused the work that had been carried out to be suspended until stability of the slopes was guaranteed. In order to achieve this objective, a visual inspection was initially carried out, later the safety factor of the slopes in their natural state was calculated. Using as geotechnical data the properties of the foundation soil obtained through the SPT tests. The calculation of the safety factor was obtained using the method of segments with established infiltration, this due to the fact that in the study area there are tropical soils, three possible fault planes were analyzed, resulting in safety factors of less than 1.00 lo that according to the norm indicates slope instability and that it is incipient to failure, the study samples were subsequently evaluated but this time considering the proposed model that consists of stabilizing the slopes using structural steel piles and metal mesh, obtaining factors as results of security greater than 4.00 that indicate stability in the slopes, being values accepted according to norm. In addition, according to the feasibility study prepared in this work, we have an economic feasibility of 36.02% using the model proposed in the project. This percentage of profitability exceeds the other conventional alternatives, so from this perspective the model is feasible. En_us
dc.description.uri Tesis es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Científica del Perú es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Estabilización de taludes es_ES
dc.subject Factor de seguridad es_ES
dc.subject Pilotes es_ES
dc.subject Mallas metálicas es_ES
dc.subject Slope stabilization En_us
dc.subject Safety factor En_us
dc.subject Piles En_us
dc.subject Metallic meshes En_us
dc.title Modelo de aplicación tecnológica para la estabilización de taludes en la cámara de bombeo pluvial Nº01 del hospital II-2 Cesar Garayar García, Iquitos 2021 es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Ingeniero Civil es_ES
thesis.degree.grantor Universidad Científica del Perú. Facultad de Ciencias e Ingeniería es_ES
thesis.degree.level Titulo Profesional es_ES
thesis.degree.discipline Ingeniería Civil es_ES
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#2.01.00 es_ES
dc.publisher.country PE es_ES
renati.advisor.dni 06755429 es_ES
renati.author.dni 73232609 es_ES
renati.author.dni 71236692 es_ES
renati.type https://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 732267 es_ES
renati.juror Wong Ramírez, Felix es_ES
renati.juror Gallardo Sánchez, Nerea es_ES
renati.juror Bautista Serpa, Liliana es_ES


Ficheros en el ítem

El ítem tiene asociados los siguientes ficheros de licencia:

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess