Evaluación del desempeño sísmico aplicando métodos estáticos no lineales en pabellones de uso esencial en la I. E. N° 41026 María Murillo De Bernal

Mostrar el registro sencillo del ítem

dc.contributor.advisor Irigoin Cabrera, Ulises Octavio
dc.contributor.author Malarin Zavaleta, Kevin Andre
dc.contributor.author Macedo Ortiz, Orlando German
dc.date.accessioned 2024-03-09T01:30:05Z
dc.date.available 2024-03-09T01:30:05Z
dc.date.issued 2024-01-25
dc.identifier.uri http://repositorio.ucp.edu.pe/handle/UCP/2792
dc.description.abstract Este proyecto de investigación, hace una “Evaluación del desempeño sísmico aplicando métodos estáticos no lineales en pabellones de uso esencial en la I. E. N° 41026 “María Murillo de Bernal””, en el departamento de Arequipa, basándose en la estructuración de elementos estructurales, aplicando la Norma Técnica Peruana E.030 de Diseño Sismorresistente. Es preciso mencionar que dicha norma, aunque se basa en fuerzas y resistencias, “no tiene un método para evaluar el desempeño estructural de una edificación, lo que significa, que no prevé el comportamiento estructural durante un evento sísmico” (Colos & Tunque, 2020). El estudio de enfoque cualitativo, aplicó el método estático no lineal y el método de coeficiente de desplazamiento (para analizar el punto de desempeño), en dos pabellones de la edificación. Los resultados mostraron que estos pabellones 101 A y 101 B, en la dirección “X”, eran operacionales y de ocupación inmediata, y en la dirección “Y”, no cumplían con el requerimiento de desempeño "Performance Based Seismic Engineering of Buildings"de 1995 del comite vision 2000”, concluyendo que, ante un evento sísmico raro, la estructura de estudio, se encontraría dentro del límite del colapso. Por otro lado, la estructura del bloque 101 A, alcanzó una ductilidad de 5.97, es decir de que presentaría una ductilidad media para la dirección de análisis X. Con respecto a la estructura del bloque 101 B, alcanzó una ductilidad de 6.45, es decir de que presentaría una ductilidad alta para la dirección de análisis X y con respecto a la dirección de análisis Y, esta última presentaría una ductilidad frágil, alcanzando un valor estático de 3.54. es_ES
dc.description.abstract This research project, performs an “Evaluation of seismic performance by applying nonlinear static methods in essential pavilions in the I.E. No. 41026 “María Murillo de Bernal””, in the department of Arequipa, based on the structure of structural elements, applishing the Peruvian Technical Standard E.030 of Seismic Resistant Design. It is worth mentioning that this standard, although it is based on forces and resistance, “has no method for evaluating the structural performance of a building, which means that it does not predict structural behavior during a seismic event.” (Colos & Tunque, 2020). The qualitative approach study applied the nonlinear static method and the displacement coefficient method (to analyze the performance point) to two building pavilions. The results showed that these pavilions 101 A and 101 B, in the “X” direction, were operational and of immediate occupation, and in “Y” direction did not meet the performance requirement “Performance Based Seismic Engineering of Buildings” of 1995 of the vision 2000 committee, concluding that in the event of a rare seismic event, the study structure would be within the boundary of collapse. On the other hand, the structure of the block 101 A, achieved a ductility of 5.97, that is to say that it would present an average ductibility for the direction of analysis X. With regard to the structure of block 101 B, it achieved a ductility of 6.45, that is to say that it would present a high ductibility for the analysis direction X and with regard to analysis direction Y, the latter would show a fragile ductility, reaching a static value of 3.54. En_us
dc.description.uri Tesis es_ES
dc.format application/pdf es_ES
dc.language.iso spa es_ES
dc.publisher Universidad Científica del Perú es_ES
dc.rights info:eu-repo/semantics/openAccess es_ES
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject Desempeño es_ES
dc.subject Pushover es_ES
dc.subject Demanda es_ES
dc.subject Sismo raro es_ES
dc.subject Colapso es_ES
dc.subject Performance En_us
dc.subject Pushover En_us
dc.subject Demand En_us
dc.subject Strange earthquake En_us
dc.subject Collapse En_us
dc.title Evaluación del desempeño sísmico aplicando métodos estáticos no lineales en pabellones de uso esencial en la I. E. N° 41026 María Murillo De Bernal es_ES
dc.type info:eu-repo/semantics/bachelorThesis es_ES
thesis.degree.name Ingeniero Civil es_ES
thesis.degree.grantor Universidad Científica del Perú. Facultad de Ciencias e Ingeniería es_ES
thesis.degree.level Titulo Profesional es_ES
thesis.degree.discipline Ingeniería Civil es_ES
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#2.01.00 es_ES
dc.publisher.country PE es_ES
renati.advisor.orcid https://orcid.org/0009-0007-6168-7415 es_ES
renati.advisor.dni 10190397 es_ES
renati.author.dni 73388017 es_ES
renati.author.dni 72966701 es_ES
renati.type https://purl.org/pe-repo/renati/type#tesis es_ES
renati.level http://purl.org/pe-repo/renati/level#tituloProfesional es_ES
renati.discipline 732267 es_ES
renati.juror Ocaña Aponte, Juan Jesús es_ES
renati.juror Wong Ramírez, Félix es_ES
renati.juror Saldaña Ferreyra, Keuson es_ES