Modelo de aplicación tecnológica para la estabilización de taludes en la cámara de bombeo pluvial Nº01 del hospital II-2 Cesar Garayar García, Iquitos 2021

dc.contributor.advisorRobalino Osorio, Miguel Angel
dc.contributor.authorSernaqué Vargas, Hugo Jeffer
dc.contributor.authorNuñez Vargas, Joyce Llolaos
dc.date.accessioned2022-06-14T14:06:10Z
dc.date.available2022-06-14T14:06:10Z
dc.date.issued2022-03-02
dc.description.abstractEl siguiente estudio permitió elaborar un modelo de aplicación tecnológica para estabilizar los taludes generados al momento de iniciar la construcción de la cámara de bombeo pluvial Nº01 del Hospital II-2 Cesar Garayar García-Iquitos, la existencia de una potencial falla hizo de que los trabajos que se venían ejecutando sean suspendidos hasta garantizar la estabilidad de los taludes, para conseguir este objetivo inicialmente se realizó una inspección visual, posteriormente se calculó el factor de seguridad de los taludes en estado natural, utilizando como datos geotécnicos las propiedades del suelo de fundación obtenidos mediante los ensayos de SPT. El cálculo del factor de seguridad se obtuvo utilizando el método de las dovelas con infiltración establecida, esto debido a que en la zona de estudio se cuentan con suelos tropicales, se analizaron tres posibles planos de fallas dando como resultados factores de seguridad menores a 1.00 lo que según el Reglamento Nacional de Edificaciones (E050-art. 30) nos indica un factor de seguridad inferior al mínimo recomendado en condiciones estáticas, posteriormente se evaluaron las muestras en estudio pero esta vez considerando el modelo propuesto que consiste en estabilizar los taludes utilizando pilotes de acero estructural y malla metálicas, obteniendo como resultados factores de seguridad mayores a 4.00 que indican estabilidad en los taludes, siendo valores aceptados según norma. Además de acuerdo al estudio de factibilidad elaborado en el presente trabajo, tenemos una factibilidad económica de 36.02% utilizando el modelo propuesto en el proyecto. Este porcentaje de rentabilidad supera las otras alternativas convencionales por lo que desde esta perspectiva el modelo es factible.es_ES
dc.description.abstractThe following study made it possible to develop a model of technological application to stabilize the slopes generated at starting time the construction of the rain pumping chamber N° 01 of Hospital II-2 Cesar Garayar García-Iquitos, the existence of a potential failure caused the work that had been carried out to be suspended until stability of the slopes was guaranteed. In order to achieve this objective, a visual inspection was initially carried out, later the safety factor of the slopes in their natural state was calculated. Using as geotechnical data the properties of the foundation soil obtained through the SPT tests. The calculation of the safety factor was obtained using the method of segments with established infiltration, this due to the fact that in the study area there are tropical soils, three possible fault planes were analyzed, resulting in safety factors of less than 1.00 lo that according to the norm indicates slope instability and that it is incipient to failure, the study samples were subsequently evaluated but this time considering the proposed model that consists of stabilizing the slopes using structural steel piles and metal mesh, obtaining factors as results of security greater than 4.00 that indicate stability in the slopes, being values accepted according to norm. In addition, according to the feasibility study prepared in this work, we have an economic feasibility of 36.02% using the model proposed in the project. This percentage of profitability exceeds the other conventional alternatives, so from this perspective the model is feasible.En_us
dc.description.uriTesises_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://hdl.handle.net/20.500.14503/1850
dc.language.isospaes_ES
dc.publisherUniversidad Científica del Perúes_ES
dc.publisher.countryPEes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.subjectEstabilización de taludeses_ES
dc.subjectFactor de seguridades_ES
dc.subjectPiloteses_ES
dc.subjectMallas metálicases_ES
dc.subjectSlope stabilizationEn_us
dc.subjectSafety factorEn_us
dc.subjectPilesEn_us
dc.subjectMetallic meshesEn_us
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_ES
dc.titleModelo de aplicación tecnológica para la estabilización de taludes en la cámara de bombeo pluvial Nº01 del hospital II-2 Cesar Garayar García, Iquitos 2021es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
renati.advisor.dni06755429es_ES
renati.author.dni73232609es_ES
renati.author.dni71236692es_ES
renati.discipline732267es_ES
renati.jurorWong Ramírez, Felixes_ES
renati.jurorGallardo Sánchez, Nereaes_ES
renati.jurorBautista Serpa, Lilianaes_ES
renati.levelhttp://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineIngeniería Civiles_ES
thesis.degree.grantorUniversidad Científica del Perú. Facultad de Ciencias e Ingenieríaes_ES
thesis.degree.levelTitulo Profesionales_ES
thesis.degree.nameIngeniero Civiles_ES

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
HUGO JEFFER SERNAQUÉ VARGAS Y JOYCE LLOLAOS NUÑEZ VARGAS - TESIS.pdf
Size:
12.98 MB
Format:
Adobe Portable Document Format
Description:
Texto Completo

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.3 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections