Comparación de la resistencia a la compresión de un concreto convencional teniendo como variable el agua utilizada en el diseño de mezcla Iquitos – 2022

dc.contributor.advisorGarcía Langer, Carol Begoña
dc.contributor.authorRengifo Vela, María Reydelinda
dc.contributor.authorHidalgo Chavez, Stephany Gianina
dc.date.accessioned2023-07-30T01:16:41Z
dc.date.available2023-07-30T01:16:41Z
dc.date.issued2023-02-06
dc.description.abstractEl presente estudio, tiene como objetivo comparar las de las resistencias a compresión de muestras de concreto (Cemento - Arena) f’c=210kg/cm2 y f’c=175kg/cm2 elaborados con diferentes tipos de aguas (Potable, Rio Itaya, Nanay y Amazonas). utilizando cemento Andino Tipo I y agregado fino para determinar si sus resistencias, uniaxiales tienen diferencia significativa. Para realizar esta investigación se elaboraron probetas de concreto en edades de 7,21 y 28 días con el fin de ver la variación de los resultados y así poder compararlos con lo establecidos por la norma. Al agua no se realizaron estudios porque se quiso ver los resultados de las resistencias de un concreto convencional como cualquier persona o empresa que realice al momento de realizar su mescla. Al agregado fino se realizó los ensayos correspondientes establecidos por la norma. Luego se realizó el ensayo de manejabilidad de concreto (prueba de slump) para medir la consistencia del concreto fresco. Después se fabricaron las probetas de concreto utilizando los diferentes tipos de aguas en diseños de 210kg/cm2 y 175kg/cm2.una vez cumplido los días de curado establecidos por la norma, se realizaron los ensayos de resistencia a compresión para corroborar si las muestras alcanzan la resistencia esperada y de esa manera saber si existe diferencia significativa. Los resultados de resistencia a la compresión uniaxial del concreto (Cemento - Arena) ensayadas y curados bajo las normas hasta los 28 días dieron los siguientes resultados: Diseño f’c =210kg/cm2; La realizada con agua potable f ‘c =349kg/cm2, La realizada con agua del rio nanay f ‘c =332kg/cm2; La realizada con agua del rio Itaya f ‘c = 315kg/cm2 y La realizada con agua del rio amazonas 349kg/cm2. Diseño f’c =175kg/cm2; La realizada con agua potable f ‘c =269kg/cm2; La realizada con agua del rio nanay f ‘c =259kg/cm2; La realizada con agua del rio Itaya f ‘c =239kg/cm2 y La realizada con agua del rio amazonas f ‘c =256kg/cm2. xv Analizando los resultados, son aceptables todos los resultados ya que los mismos sobrepasan al f’c de diseño. También se ve que el diseño realizado con agua del rio Itaya tiene menor promedio de resistencia a la compresión, el diseño realizado con el agua de rio amazonas tiene el mayor promedio de resistencia a la compresión, ninguno de los ensayos realizados estan por debajo del diseño establecido. Finalmente se concluye que si se puede utilizar los diferentes tipos de aguas (Agua Potable, Agua del Rio Nanay, Agua del Rio Itaya, Agua del Rio Amazonas), que se vio en este estudio en la elaboración del concreto. Por lo tanto, NO EXISTE DIFERENCIA SIGNIFICATIVA al utilizar diferentes tipos de agua (agua potable y aguas superficiales) en él diseño de mezcla la cual responde a nuestra hipótesis.es_ES
dc.description.abstractThe objective of this study is to compare the compressive strength of concrete samples (Cement - Sand) f'c=210kg/cm2 and f'c=175kg/cm2 made with different types of water (Potable, Itaya River, Nanay and Amazon). using Andean Type I cement and fine aggregate to determine if their uniaxial resistances have a significant difference. To carry out this investigation, concrete test tubes were made at ages of 7, 21 and 28 days in order to see the variation of the results and thus be able to compare them with what is established by the standard. No studies were carried out on water because they wanted to see the results of the resistance of a conventional concrete like any person or company that carries out at the time of mixing. The corresponding tests established by the standard were carried out on the fine aggregate. Then the concrete workability test (slump test) was carried out to measure the consistency of the fresh concrete. Afterwards, the concrete test tubes were manufactured using the different types of water in 210kg/cm2 and 175kg/cm2 designs. Once the curing days established by the standard were completed, the compression resistance tests were carried out to confirm if the samples reached the expected resistance and thus know if there is a significant difference. The results of resistance to uniaxial compression of concrete (Cement - Sand) tested and cured under the standards up to 28 days gave the following results: Design f'c =210kg/cm2; The one made with drinking water f ‘c =349kg/cm2, The one made with water from the Nanay river f ‘c =332kg/cm2; The one made with water from the Itaya river f ‘c = 315kg/cm2 and the one made with water from the Amazon river 349kg/cm2. Design f'c =175kg/cm2; The one made with drinking water f ‘c =269kg/cm2; The one made with water from the Nanay river f ‘c =259kg/cm2; The one made with water from the Itaya river f ‘c xvii =239kg/cm2 and the one made with water from the Amazon river f ‘c =256kg/cm2. Analyzing the results, all the results are acceptable since they exceed the design f'c. It is also seen that the design made with water from the Itaya river has a lower average compressive strength, the design made with Amazon River water has the highest average compressive strength, none of the tests carried out are below the design established. Finally, it is concluded that it is possible to use the different types of water (Potable Water, Nanay River Water, Itaya River Water, Amazon River Water), which was seen in this study in the preparation of concrete. Therefore, THERE IS NO SIGNIFICANT DIFFERENCE when using different types of water (drinking water and surface water) in the mix design which responds to our hypothesis.En_us
dc.description.uriTesises_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://hdl.handle.net/20.500.14503/2500
dc.language.isospaes_ES
dc.publisherUniversidad Científica del Perúes_ES
dc.publisher.countryPEes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/*
dc.sourceRepositorio Institucional Universidad Científica del Perú
dc.subjectProbetases_ES
dc.subjectUniaxiales_ES
dc.subjectConcretoes_ES
dc.subjectSuperficialeses_ES
dc.subjectSpecimensEn_us
dc.subjectUniaxialEn_us
dc.subjectConcreteEn_us
dc.subjectSuperficialEn_us
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_ES
dc.titleComparación de la resistencia a la compresión de un concreto convencional teniendo como variable el agua utilizada en el diseño de mezcla Iquitos – 2022es_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
renati.advisor.dni32885913es_ES
renati.advisor.orcidhttps://orcid.org/0009-0007-5448-5727es_ES
renati.author.dni76598140es_ES
renati.author.dni72946493es_ES
renati.discipline732267es_ES
renati.jurorWong Ramírez, Félixes_ES
renati.jurorIrigoin Cabrera, Ulises Octavioes_ES
renati.jurorOcaña Aponte, Juan Jesúses_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineIngeniería Civiles_ES
thesis.degree.grantorUniversidad Científica del Perú. Facultad de Ciencias e Ingenieríaes_ES
thesis.degree.levelTitulo Profesionales_ES
thesis.degree.nameIngeniero Civiles_ES

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
TESIS_MARÍA RENGIFO Y STEPHANY HIDALGO.pdf
Size:
4.09 MB
Format:
Adobe Portable Document Format
Description:
Texto completo

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.3 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections