Influencia de la adición de fibra sika fiber force 48, en la relación entre la resistencia a la compresión y el módulo de rotura del concreto cemento-arena, Iquitos – 2024

dc.contributor.advisorCabanillas Oliva, Erlin Guillermo
dc.contributor.authorÁlvarez Naveros, Joe Lee
dc.contributor.authorBravo Saavedra, Wilmer Mercedes
dc.date.accessioned2026-02-06T16:14:40Z
dc.date.available2026-02-06T16:14:40Zes_ES
dc.date.issued2026-01-13
dc.description.abstractLa investigación determinó la influencia de la adición de Sika Fiber Force - 48, en la correlación entre la resistencia a la compresión y el módulo de ruptura (MR) del concreto cemento - arena, Iquitos – 2024, elaborado con agregado fino de 1.20 de módulo de fineza. La investigación es de tipo cuantitativo; de nivel descriptivo y explicativo; de diseño cuasi experimental. La muestra estuvo conformada por 198 probetas, de las cuales 99 corresponden a la muestra patrón y 99 a la muestra experimental con relaciones A/C = 0.58, 0.63 y 0.68 y cuatro dosificaciones de macrofibra: 0.00 kg/m3, 0.50kg/m3, 0.70kg/m3 y 0.90kg/m3, siendo evaluadas a los 7 y 28 días de curado. La adición de las macrofibras sintéticas Sika Fiber Force – 48 en la mezcla de concreto cemento-arena, influye en la resistencia a la compresión medida en kg/cm2 y a los 28 días de curado. El concreto patrón, para A/C=0.58 alcanzó 310; para A/C=0.63 un valor de 277; y, para la A/C=0.68 una resistencia de 224. Para el experimental, una dosis de fibra de 0.50% y, relación A/C=0.58 la resistencia varió a 323; A/C=0.63 a 296 y para A/C=0.68 fue de 229; para una dosis de 0.70% de fibra y, la A/C=0.58 esta resistencia fue de 333; para la A/C=0.63 el valor fue 301, A/C=0.68 fue de 237; y, para 0.90% de fibra, A/C=0.58 la resistencia alcanzó 296, con A/C=0.63 fue 259, y para A/C=0.68 fue 12kg/cm2; resultando óptimo para la compresión la dosis de 0.70% fibra. Para el concreto patrón, la resistencia a la Flexión (en kg/cm², 28 días), para una relación A/C=0.58 alcanzó 38, A/C=0.63 alcanzó 35 y para A/C=0.68 alcanzó 31. Para el experimental y dosis de fibra de 0.50%, la resistencia a la flexión fue de 41, 37 y 33; para 0.70% fue de 39, 34 y 32; y para el 0.90% de fibra fue de 43, 39 y 30. La mejor flexión obtenida fue con 0.90% de fibras. Los modelos matemáticos para predecir la resistencia a la flexión a partir de la compresión (relaciones f’c vs fr) se ajustan a tipos de ecuaciones lineales y potenciales (R² casi perfecto, 0.996 – 0.997).es_ES
dc.description.abstractThe investigation determined the influence of the addition of Sika Fiber Force-48, on the correlation between the Compressive strength and the modulus of rupture (MR) of cement-sand concrete, Iquitos-2024, manufactured with fine aggregate of 1.20 fineness moulus. The research is kind of quantitative, of descriptive and explanatory leveland levela quasi-experimented in design. The Sample was formed by 198 specimens (testpines) of Which 99 corresponded to the standard sample and 99 to the experimental sample with water-cement ratios of 0.58, 0.63, and 0.68 and four macrofiber dag dosages. Kg/m³, 0,50 kg/m³, 0.70 kgm, and kg/m³, evaluated after seven (7) and twenty night (28 2 days of curing. The addition of Sika Fiber Force 48 synthetic macrofibers to the cement - sand concrete mix, influences on the Compressive strength measured in kg/cm² after 28 days of curling. The concrete pattern, with a w/c ratio of 0.58, reached 310, with w/c ratio of 0.63, a value of 277, and with ratio of ass a strength of 224. For the experimental mix, with a fiber dosage of 0.50% and W/C ratio 0.58, the strength varied to 323; with W/k ratio of 0.03, to 296; and with w/C ratio of 0.68, it was 229. with a fiber dosage of 0.70% and a W/c ratio of 0.68, it was 237, and for 0.90% fiber, with a water cement ratio (W/c) of 0.58, the compressive strength reached 296 kg/cm², with w/C of a.63, it was 259 Kg/cm², and with w/c of 0.68, it was 12 kg/cm². the optimal dosage for optimal results for compression found to be 0.70% of fiber, and for the Concrete pattern, the flexural strength(in kg/cm² 28 day) for a w/k ratio of 0.58 reached 3 kg/cm², for w/k o.cs, it reached 35 kg/cm², and for w/c of 0.68. It reached 31 kg/cm². For the experimental mér and Fiber dosage of 0.50% the floaral strength was 41 kg/cm², 37 kg/cm², and 33 kg/em³, for w/c of 0.70% was 39, 34, 32 kg/cm² and for W/k of 0.90% of Fiber; it was 43,39,30 kg/cm². the best flexural strength obtained was 0.90% of Fiber. The mathematical models for predicting Flexural strength from compression (fc vs. fr relationships) fit linear and power law equation types (almost perfect R2, 0.996-0.997).En_us
dc.description.uriTesises_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://hdl.handle.net/20.500.14503/3569
dc.language.isospaes_ES
dc.publisherUniversidad Científica del Perúes_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2es_ES
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.subjectConcreto cemento-arenaes_ES
dc.subjectMódulo de rupturaes_ES
dc.subjectResistencia a la compresiónes_ES
dc.subjectCement-sand concreteEn_us
dc.subjectMoulus of rupture and compressive strengthEn_us
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.01.00es_ES
dc.titleInfluencia de la adición de fibra sika fiber force 48, en la relación entre la resistencia a la compresión y el módulo de rotura del concreto cemento-arena, Iquitos – 2024es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
renati.advisor.dni27166222es_ES
renati.advisor.orcidhttps://orcid.org/0000-0001-9815-6828es_ES
renati.author.dni80227979es_ES
renati.author.dni15643560es_ES
renati.discipline73200082es_ES
renati.jurorIrigoin Cabrera, Octavio Uliseses_ES
renati.jurorWong Ramírez, Félixes_ES
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesionales_ES
renati.typehttps://purl.org/pe-repo/renati/type#tesises_ES
thesis.degree.disciplineIngeniería Civiles_ES
thesis.degree.grantorUniversidad Científica del Perú. Facultad de Ciencias e Ingenieríaes_ES
thesis.degree.nameIngeniero Civiles_ES

Files

Original bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
Ficha de autorizacion - Alvarez - Bravo.pdf
Size:
6.79 MB
Format:
Adobe Portable Document Format
No Thumbnail Available
Name:
Álvarez Naveros, Joe Lee y Bravo Saavedra, Wilmer Mercedes – TESIS – ING. CIVIL.pdf
Size:
2.58 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections